Tugas Akhir
investigation of transformer sst1 oil quality with comparison of dissolved gas analysis method at pltgu grati / Shandy Krisnawan
Abstrak
Krisnawan Shandy 2025. Investigation of Transformer SST1 Oil Quality with Comparison of Dissolved Gas Analysis Method at PLTGU Grati. Final Project D4 Energy Power Plant Engineering Technology Study Program Vocational Faculty University of Malang. Supervisor Sujito. S.T. M.T. Ph.D. Keywords Transformer Oil Insulation Dissolved Gas Analysis (DGA) Gas PLN Indonesia Power Grati Power Generation Business Unit is a gas and steam power plant. Based on electrical data monitoring the Tan delta value of 1.703% on the high-voltage bushing side of the V Station State Transformer 1 150/6.3 kV 30 MVA was found to be significantly above the IEEE C57. 12 which requires a Tan delta value lt 0.5% accompanied by losses of 259.29 mW. This amount of power loss indicates energy being converted into heat increasing the risk of overheating and further insulation damage to the transformer. The purpose of this study is to analyze the technical problems of the isolation system and provide solutions for the 150/6.3 kV 30 MVA Station State Transformer 1 power transformer that has been operating at the PT PLN Indonesia Power UBP Grati PLTGU since 1998. Using six DGA analysis methods namely Key Gas Duval Triangle Roger rsquo s Ratio Ronsberg Ratio Doernenburg Ratio and TDCG to identify potential internal faults. The results were interpreted in accordance with international standards IEC 60599 IEEE C57.104-2008 and SPLN 114 1999 to determine the type of fault and the level of concern regarding the transformer rsquo s condition. This testing aims to detect early changes or anomalies in dissolved gas content which indicate types of damage such as overheating arcing and partial discharge. The DGA method has proven effective as a diagnostic tool for detecting the type and extent of internal transformer damage. Based on the results of six DGA analysis methods a comprehensive diagnostic overview is provided which is more accurate than using a single DGA analysis method alone. Regular monitoring and comparison of results over time are crucial for detecting early signs of internal faults before damage occurs to the transformer.