Abstrak
ABSTRAK Kurniawan Yalius. 2017.ATS (Automatic Transfer Switch) Genset dengan Sistem Kontrol Pemanasan Genset Otomatis Secara Berkala Berbasis Mikrokontroler. Tugas Akhir. Program Studi D3 Teknik Elektro. Jurusan Teknik Elektro. Fakultas Teknik. Universitas Negeri Malang. Pembimbing Dyah Lestari S.T. M.Eng. Kata Kunci Automatic Transfer Switch Pemansan Genset Mikrokontroler. Seiring dengan meningkatnya jumlah pembangunan khususnya di bidang industri menyebabkan permintaan akan energi listrik semakin bertambah. Namun kemampuan PLN sebagai penyedia utama suplai listrik sangat terbatas bahkan cenderung menurun maka diperlukan backup power yang handal misalnya Genset (Generator Set). Namun untuk memindah daya ke genset maka diperlukan sistem kendali Automatic Transfer Switch (ATS). ATS adalah sebuah sistem untuk melakukan perpindahan daya secara otomatis dari sumber daya utama PLN ke sumber daya cadangan genset. ATS juga bisa dikombinasikan dengan sistempemanasan genset otomatis secara berkala sebagai bagian dari maintenance genset.Kontrolutama dari sistem ini adalahArduino Uno R3 dimana Arduino yang mengontrolRelayDC 5V yang kemudian mengaktifkan Relay AC 220V untuk melakukan peralihan daya . Dalam hal ini sensor yang digunakan untuk mendeteksi tegangan adalah sensor ZMPT 101 B. Untuk pemanasan genset digunakan modul RTC DS1307 yang akan menampilkan waktu secara real timekemudian Arduino diprogram untuk memerintah sistem melakukan pemansan genset pada jam 06.00-06.10. Pengujian sistem ATS (Automatic Transfer Switch) genset dengan sistem kontrol pemanasan genset otomatis secara berkala berbasis mikrokontroler diketahui hasilnyayaitusaat PLN padammakadayaakandialihkankegensetkemudianmikrokontrolerakanmenyalakangensetsecaraotomatis.Begitu pula saat PLN kembalimenyalamakadayadialihkankembalike PLN lalumikrokontrolerakanmematikangensetsecaraotomatis. Padasaat jam 06.00 mikrokontrolerakanmemerintahgensetuntukmenyalasebagai proses pemanasan. Gensetakanmatisecaraotomatispada jam 06.10. ABSTRACT Kurniawan Yalius. 2017.Generator Set ATS with Periodically Warming Control System Based on Microcontroller. Final Project. Diploma 3 of Electrical Engineering. Department of Electrical Enginering. Faculty ofEngineering. Universitas Negeri Malang. Supervisor Dyah Lestari S.T. M.Eng. Keywords Auto Transfer Switch Generator Set Heating Microcontroller. Along with the increasing number of development especially in the field of industry led to the demand for electricity grew.However the ability of major providers as supply PLN S power was limited even tend to decline then needed a reliable power backups for example of Generator Set. However to switch the power to the generator control system required theAutomatic Transfer Switch (ATS). ATS is a system to automatically power make the shift from primary resource PLN to resources backup generator.ATS can also be combined with automatic gennerator set warming system periodically as part of the maintenance of generator. This system of Hardwere is Arduino Uno R3 where the Arduino which control Relay DC 5V which then enable Relay AC 220V to do the transition of power.In this case the sensor is used to detect the voltage sensor is ZMPT 101 B.To warm up the generator set is used the DS1307 RTC module will display the time in real time then the arduino is programmed to perform system reigning generator set warming at 06.00 06.10. The system testing ofGenerator Set ATS with Periodically Warming Control System Based on Microcontrollerknown result that is When the power goes out then power the PLN will be redirected to the gensetand then the microcontroller will turn on the generator automatically.Similarly while PLN back lit then the power transferred back to PLN then the microcontroller will turn off the generator automatically. At the time of 06.00 microcontroller will govern the genset to turn on the generator automatically as the process of warming.Genset will turn off automatically at 06.10.


Informasi Detail
DDC
Rp 621.313 KUR a
Prodi
Universitas Negeri Malang. Program Studi Diploma III Teknik Elektro, 2017.
Deskripsi Fisik
xiii, 63 lembar : il. , tab. ; 30 cm
Bahasa
Indonesia
No Reg
04902/KI/17
Edisi
Tugas Akhir (Diploma)--Universitas Negeri Malang. 2017
Subjek
1. GENSET
2. GENERATOR MACHINERY

Pembimbing
1. Dyah Lestari
Lampiran Berkas
You must be logged in to get fulltext


UPT Perpustakaan UM
  • Berita

Tentang Kami

TIM IT Perpustakaan 2023

Cari

masukkan satu atau lebih kata kunci dari judul, pengarang, atau subjek

Donasi untuk SLiMS

Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik